Product Overview
WOOFAA Bcon is an all-rounded air monitor which works well with different IoT network protocols and deployment context.
Six air quality parameters are available as a standard offer: PM2.5, PM10, CO2, TVOC, Air Temperature and Relative Humidity. Optional offers include formaldehyde, CO and ozone.
To become part of a network, Bcon data can be transferred to server via RS485 for Modbus RTU, 433MHz radio frequency, GPRS and 2.4GHz WiFi communication.
Apart from our data server, data can be sent to any third-party system for data integration or local visualization in protocols as MQTT or RESTful API.
Main Features
- Multiple measurement parameters: PM2.5, PM10, TVOC, HCHO, CO, CO2, temperature, relative humidity
- Power source: 110-240VAC or 8-30VDC
- Communication protocols: RS485 / GPRS / RF433 / WiFi / Modbus
- WOOFAA BCon series products can be integrated with 86 box, support RS485, wireless 433 protocols.
- Can be customized to accommodate specific request, such as monitoring sulphur dioxide and oxygen gas concentration.
- Support mobile app, upper computer and web-based remote control. Intelligent control by Internet
Technical Specifications
- PM2.5 and PM10 using laser scattering measurement
- Measuring Range: 0.3 to 10 µm
- Measuring Threshold: 0 to 500 μg/m³
- Counting Effectiveness: 50% @ 0.3 μm, 98% @ ≥ 5 μm
- Accuracy: ±10%
- Measuring Volume: 0.1 L
- Response Time: ≤10 seconds
- TVOC using semiconductor sensor
- Measuring Range: 0 to 3.00 mg /m³ (Milli gram)
- Accuracy: ±15%
- Response Time: < 5 seconds
- Warm-up Time: 15 minutes
- Carbon Dioxide (CO2) using NDIR measurement
- Measuring range: 400 ~ 2000 ppm
- Temperature Coefficient: 0.2% FS /℃
- Temperature Calibration: Auto
- Measuring Accuracy: 22℃ (72℉) ± 45ppm ± 3%
- Stability: Within the life cycle (15 years), < 2% of the full measuring threshold
- Calibration Cycle ABC Logic self-calibration (no user input required)
- Nonlinear: < 1% Full Scale
- Pressure Coefficient: 0.13% mmHg input
- Reaction Time: < 2 minutes for 90% of change
- Refresh Rate: 2 seconds
- Warm-up Time: < 2 minutes (operation), 10 minutes (maximum accuracy)
- Resolution: 1 ppm
- Carbon Monoxide (CO) using Electrochemical Measuring Method
- Measuring Range: 0 ~ 500 ppm
- Measuring Accuracy: 0.1 ppm
- Warm-up Time: ≤ 3 minutes
- Reaction Time: ≤ 60 seconds
- Recovery Time: ≤ 60 seconds
- Working Humidity: 15% ~ 65% Relative Humidity
- Formaldehyde (HCHO) using Electrochemical Measuring Method
- Measuring Range: 0 ~ 5 mg/m3
- Measuring Accuracy: ≤ 01 mg/m3
- Warm-up Time: ≤ 3 minutes
- Reaction Time: < 30 seconds
- Working Temperature: 0 ~ 50℃
- Working Humidity: 15% ~ 90% Relative Humidity
- Temperature
- Working Range: -40 ~ +125℃
- Resolution: 1℃
- Accuracy: ±1℃
- Repeatability: ±1℃
- Response Time: 5 seconds
- Long Time Drifting: < 0.04°C / year
- Relative Humidity
- Working Range: 0 ~ 100%
- Resolution: 1%
- Accuracy: ±2%
- Repeatability: ±1%
- Lag: ±1%
- Nonlinear: < 0.1%
- Response Time: 8 seconds
- Long Time Drifting: < 0.5% / year
- Work Status Display: 3 indicator light combination display
- Power Consumption: 3 ~ 5W (depend on the number of parameters)
- Power Supply: 8-30VDC / 110-230VAC, 50/60HZ
- Cable Entry: RS485 Screw Terminal 8-pins block
- Housing Material: ABS
- Overall Dimensions: Diameter 170 x Height 50mm
- Net Weight: 380g