WOOFAA Cee

Wireless Industrial Gas Monitor Configurable Sensors
Now you can get tailor-made wireless monitor on WIFI, the WOOFAA Cee, customized with electrochemical industrial gas type sensors for your application: Smart Carpark, Smart Toilet, Smart Kitchen, Smart Refuse and more.
WOOFAA Cee is a part of the WOOFAA Air system, which is a visualization and analytic cloud data platform with automatic daily PDF reporting function with insights.
Order WOOFAA CeeExplore WOOFAA Air

Electrochemical Gas Sensor

WOOFAA Cee industrial gas monitor is using solid-state electrochemical gas sensors, which not only giving a higher measuring range and  resolution on PPB level, it also has a much long er (5-10 years) product life versus conventional type (1-3 years), with a price tag of nearly 70% off.

Deployment in Smart Carpark can automatically and safely reduce ventilation energy saving up to 30%.

The magic is on and advanced high polymer technology from Germany, with which the conventional liquid-state electrochemical sensor method is replaced by solid-state. This advanced tech brings in advantages such as:

  • Industrial grade precision (accuracy, repeatability & linearity), superior performance above all semiconductive and MEMS type sensors
  • PPB (parts-per-billion) resolution, against to PPM (parts-per-million) on semiconductive and MEMS type sensors
  • Less data drifting over time, no calibration is ever needed over its product life
  • Faster response time, quicker zero recovery, no warm-up time due to its low temperature resistance
  • Immunes towards electromagnetic interference, resulting a lower-cost hardware construction to work with AC power supply and WIFI signals on the same PC board
  • Works well in very dry ambient, as the high polymer file is insensitive to humidity changes
  • Works well in vacuum or anoxic ambient
  • Compact size
  • One-third or one-fourth of price to conventional liquid-state electrochemical type sensors
  • Compliance:
    • RoHS
    • EMC: EN55022 and FCC
    • EU 2002/231/CE Directive
    • EN 13779:2007
    • GB 12358:2006
    • GB 50325:2010
    • GB 3095:1996
    • GB/T 18883:2002
    • TW Indoor Air Quality Standards
Gas Sensor Conformance Test - For sensor calibration and consistency test

Excellent data consistency and linearity across multiple industrial gas type, in high polymer solid-state electrochemical sensor adopted in WOOFAA Cee

Sensor Quick Selection Guide

Code | Gas Type | Measure Range | Resolution

  • X_5A | Carbon Monoxide (CO) | 0~10 ppm | 1 ppb | [Explore]
  • X_5B | Carbon Monoxide (CO) | 0~100 ppm | 100 ppb | [Explore]
  • X_5C | Carbon Monoxide (CO) | 0~500 ppm | 100 ppb | [Explore]
  • X_5D | Carbon Monoxide (CO) | 0~1000+ ppm | 100 ppb | [Explore]
  • X_7A | Hydrogen (H2) | 0~4 % | 0.01 % Vol
  • X_7B | Hydrogen (H2) | 0~1000 ppm | 1 ppm
  • X_9A | Hydrogen Sulfide (H2S) | 0~2 ppm | 1 ppb
  • X_9B | Hydrogen Sulfide (H2S) | 0~10 ppm | 1 ppb
  • X_9C | Hydrogen Sulfide (H2S) | 0~100 ppm | 100 ppb
  • X_H1 | Formaldehyde (HCHO) | 0~1 ppm | 1 ppb | [Explore]
  • X_H3 | Formaldehyde (HCHO) | 0~5 ppm | 1 ppb
  • X_H5 | Formaldehyde (HCHO) | 0~100 ppm | 10 ppb
  • X_J1 | General IAQ | 0~10 ppm | 1 ppb | [Explore]
  • X_J3 | General IAQ | 0~200 ppm | 100 ppb
  • X_N1 | Nitrogen Dioxide (NO2) | 0~5 ppm | 1 ppb
  • X_N3 | Nitrogen Dioxide (NO2) | 0~50 ppm | 10 ppb
  • X_N5 | Nitrogen Dioxide (NO2) | 0~100 ppm | 100 ppb
  • X_QQ | Oxygen (O2) | 0~25 % | 0.01 % Vol
  • X_Q1 | Ozone (O3) | 0~5 ppm | 1 ppb
  • X_Q3 | Ozone (O3) | 0~50 ppm | 10 ppb
  • X_Q5 | Ozone (O3) | 0~100 ppm | 100 ppb
  • X_M1 | General Smell | 0~5 ppm | 1 ppb | [Explore]
  • X_M3 | General Smell | 0~500 ppm | 10 ppb
  • X_K1 | Combustion Smoke | 0~100 ppm | 10 ppb | [Explore]
  • X_S1 | Sulfur Dioxide (SO2) | 0~5 ppm | 1 ppb
  • X_S3 | Sulfur Dioxide (SO2) | 0~50 ppm | 10 ppb
  • X_S5 | Sulfur Dioxide (SO2) | 0~100 ppm | 100 ppb
  • X_T1 | Volatile Organic Compounds (VOCs) | 0~10 ppm | 1 ppb
  • X_T3 | Volatile Organic Compounds (VOCs) | 0~500 ppm | 10 ppb
  • X_T5 | Volatile Organic Compounds (VOCs) | 0~2000 ppm | 100 ppb
  • Y_1 | Carbon Dioxide (CO2) | 0~5000 ppm ± 10% | 1 ppm
  • Y_3 | Carbon Dioxide (CO2) | 0~5000 ppm ± 3% | 1 ppm
  • Y_5 | Carbon Dioxide (CO2) | 0~10000 ppm ± 3% | 1 ppm
  • Y_2 | Particle Sensor (PM2.5) | 0~500 µg/m3 ± 15% | 1 µg/m3
  • Y_4 | Particle Sensor (PM2.5) | 0~1000 µg/m3 ± 15% | 1 µg/m3

Technical Specifications

The data listed here is for general reference only. Details may various on specific gas type. Please contact us for technical sheet of specific gas type.

Available gas quality type sensors: Cl2, CO, CO2, H2, H2S, HCHO, IAQ, NH3, O2, O3, Smell, Smoke, NO2, SO2, TVOC, PM2.5/PM10, air temperature and relative humidity.

  • Response time: < 3s
  • Accuracy: ±5% FS
  • Repeatability: ±1% FS
  • Consistency: > 95%
  • Resolution: 1% or 10 ppb
  • Life-time baseline drift: < 0.5% FS, or < 50 ppb for FS < 10 ppm
  • Power rating: 3.3~5.5V DC, < 5 mA working current, 25 mW @ 5V DC
  • No need of pre-heating
  • No interference from gaseous chlorine dioxide disinfectant
  • No sign of damage being exposed long-term to corrosive gases H2S, Cl2, HCL, and SOx
  • No sensor toxication in high concentration of contaminant, even amid in fume and gaseous silicon compounds
  • Built-in temperature sensor in each module for automatic nonlinearity compensation
  • Calibration: no need, sensor module has self-correction function built-in
  • Working temperature: -20~55 °C
  • Operating humidity: 10%~95% RH non-condensing
  • Product life: 5~10 years in indoor installation
Proprietary sensor calibration and baseline adjustment appliance

Proprietary sensor calibration and baseline adjustment appliance

WOOFAA Cee Offers Configurable Sensor Options as per Your Project Needs

WOOFAA Cee offers configurable industrial gas sensor options as per your project needs

Job Reference: Hong Kong Construction Industry Trade Testing Centre

Job Reference: Hong Kong Construction Industry Trade Testing Centre

HKCITTC is a vocational training center for construction workers. Apart from general IAQ wireless monitoring (on PM2.5, VOC, Room Temperature and Relativity Humidity), there are few welding zones where the management wanted to monitor two specific types of industrial gas for safety purpose: carbon monoxide (CO) and acetylene (C2H2).

Conventional industrial grade CO and C2H2 gas detectors are expensive and bulky if made to work wirelessly. Our WOOFAA Cee made an excellent alternative hardware in terms of both performance and time to deployment.

Shop Categories

Air Quality Monitors
Air Purifiers
Tools & Consumables

Save your portion of HK$3.84B money you might be contributing

for the medical cost (COI, cost-of-illness) Hong Kong has been paying yearly as a result of bad air quality <ref>,⁣ in only THREE simple steps:

(1) Measure、(2) Purify、(3) own healthy breathing air and live better in your home and workplace.
Copyright © 2024 WOOFAA Company Limited 鏸發有限公司 | Hong Kong | t: +852 2649 4000 | e: [email protected] | 威富商行备案号:粤ICP备17078238号